Find everything you need for the water analysis in the boiler house in this Heyl analysis set:
We offer individual versions, if you want a different composition.
Content of Analysis Case Boiler House:Titration sets: 1 Duroval A, 1 Duroval B, 1 Duroval CPM Testoval colour comparison kits: 1 sulphite, 1 phosphate test 1 pH tester pHep+ 1x 20ml buffer solution pH 4.01 in a sachet 2x 20ml buffer solution pH 7.01 in a sachet 1x 20ml electrode cleaning solution in a sachet 1 conductivity tester DiST 44x 20ml conductivity solution 12.880 μS/cm in a sachet
The practical premium analysis case boiler house contains a complete hand-held laboratory for checking the feed water quality.
The professional, combined multi parameter conductivity and pH measuring instrument has two replaceable probes.
Contents: Professional combined conductivity and pH value measuring instrument with exchangeable probes for determining the main parameter conductivity in the range of 0.00 to 200 mS/cm with a resolution of 0.01 - 0.1 - 1 µS / mS (automatic) and the pH value in the range of 0 to 14.00 (Plus Version -2.00 to 16.00) with a resolution / accuracy of 0.1 pH (Plus Version 0.01 / +0.02). In addition, the TDS value and temperature can be displayed and the instrument has an automatic temperature compensation 0-80°C (Plus Version 0 to 100°C). With an additional available ORP probe you can measure the oxidation reduction potential.Duroval A water hardness test set complete with measuring tube, indicator, dosing pipette calibrated 0-30 °dH and 50 ml titration solution for approx. 100 analyses with measuring time: approx. 2 minutesDuroval B water hardness test set complete with measuring tube, indicator, dispensing pipette calibrated 0-2 °dH and 50 ml titration solution for approx. 100 analyses with a measuring time of approx. 2 minutesDuroval CPM test set complete with measuring tube, indicator, dosing pipette calibrated 0-20 °dH carbonate hardness, p-value (acid capacity up to pH 8.2; KS 8.2) and m-value (acid capacity up to pH 4.3; KS 4.3) and 50 ml titration solution for approx. 200 analyses with measuring time: approx. 2 minutesConductivity Calibration Solution EC 12880 μS/cm, +-1% @25°C, 1 bottle a 70ml
Buffer solution pH 4.01, +-1% @25°C, 1 bottle a 70mlBuffer solution pH 7.01, +-1% @25°C, 1 bottle a 70mlMeasuring cup 100 ml
Black plastic case with red closure
Our portable multi-parameter measuring device with innovative high-resolution colour display is suitable for working in all conditions and offers you an integrated user-friendly guide in the form of the set-up and calibration mode. This allows the user to easily and intuitively use the instrument at any time.
The meter has automatic pH calibration with USA and NIST buffers with up to three points for pH and one point for ORP. Up to five fixed points, as well as one individual calibration point, are available for calibrating the conductivity electrode. You are supported by an intuitive symbolism on the backlit screen, including the indication of the measurement stability (adjustable) and any errors. Another advantage is that the multi-parameter meter is delivered in our professional measuring case, which contains the selected measuring electrodes, as well as our respective buffer solutions and the instructions.
Complementary advantages of the Professional Plus version:
GLP functions: Date and time, recall of calibration data and "Calibration due" function
Integrated data logger for up to 1000 data, automatic and manual
PC connection via USB for evaluation of measurement data (Micro-USB on the instrument side) via Data Link+ software
Automatic brightness control of the display (prolongs battery life)
Only 6 keys for easy control of all functions of the unit
230V power supply unit
The practical analysis case contains a complete hand-held laboratory for testing the filling water of heating systems according to VDI guideline 2035.
The conductivity meter and pH meter are IP65 certified, which means "dust-tight and protected against water jets" and have replaceable probes.
Contents:
Electronic conductivity meter with exchangeable probe for determining the conductivity in the range 0-3999 μS/cm with a resolution of 1 μS/cm and the TDS value in the range 0-2000PPM with a resolution of 1 PPM. Automatic temperature compensation 0-60°C. IP65. Conductivity Calibration Solution EC 1413 μS/cm, +-1% @25°C, 5 bags a 20ml
Electronic pH meter with exchangeable probe for determining the pH value in the range of 0.0-14.0 with a resolution of 0.1 pH
Buffer solution pH 4.01, +-1% @25°C, 5 bags of 20ml
Buffer solution pH 7.01, +-1% @25°C, 5 bags of 20ml
Buffer solution pH 10.01, +-1% @25°C, 5 bags of 20ml
Duroval A complete with measuring tube, indicator, dosing pipette calibrated 0-30 °dH and 50 ml titration solution for approx. 100 analyses with measuring time: approx. 2 minutes.
Duroval B complete with measuring tube, indicator, dispensing pipette calibrated 0-2 °dH and 50 ml titration solution for approx. 100 analyses with a measuring time of approx. 2 minutes
According to VDI Guideline 2035, Sheet 2, changes in the pH value or excessive electrical conductivity (LF) in hot water heating systems should be avoided to prevent corrosion damage to heating systems. With the help of our supplied solutions, indicators and testers, an optimal control and monitoring of the relevant values can take place. The appropriate values for your heating system can be found in the VDI guideline 2035.
We regularly carry out team training courses for facility managers and heating installers in the correct application. Please contact us.
The practical analysis case contains a complete hand-held laboratory for testing the filling water of heating systems according to VDI guideline 2035.
The conductivity meter and pH meter are IP65 certified, which means "dust-tight and protected against water jets" and have replaceable probes.
Contents:
Electronic conductivity meter with exchangeable probe for determining the conductivity in the range 0-3999 μS/cm with a resolution of 1 μS/cm and the TDS value in the range 0-2000PPM with a resolution of 1 PPM. Automatic temperature compensation 0-60°C. IP65! Conductivity Calibration Solution EC 1413 μS/cm, +-1% @25°C, 5 bags a 20ml
Electronic pH meter with exchangeable probe for determining the pH value in the range of 0.0-14.0 with a resolution of 0.1 pH
Buffer solution pH 4.01, +-1% @25°C, 5 bags of 20ml
Buffer solution pH 7.01, +-1% @25°C, 5 bags of 20ml
Buffer solution pH 10.01, +-1% @25°C, 5 bags of 20ml
Duroval A complete with measuring tube, indicator, dosing pipette calibrated 0-30 °dH and 50 ml titration solution for approx. 100 analyses with measuring time: approx. 2 minutes.
Duroval B complete with measuring tube, indicator, dispensing pipette calibrated 0-2 °dH and 50 ml titration solution for approx. 100 analyses with a measuring time of approx. 2 minutes
According to VDI Guideline 2035, Sheet 2, changes in the pH value or excessive electrical conductivity (LF) in hot water heating systems should be avoided to prevent corrosion damage to heating systems. With the help of our supplied solutions, indicators and testers, an optimal control and monitoring of the relevant values can take place. The appropriate values for your heating system can be found in the VDI guideline 2035.
We regularly carry out team training courses for facility managers and heating installers in the correct application. Please contact us.